Features

  • MPO / MTP connector interface patch cord
  • Customizable fiber optic cable length
  • Available in 12 and 24 core cable fiber types
  • Uses multi-mode 50/125um, OM3 /OM4 Bend-insensitive fiber or single-mode (G652D, G657A1) Bend-insensitive fiber types with type 2mm diameter
  • Comply with IEC 61754-7, Telcordia GR-1435-CORE
  • RoHS 6 compliant(lead free)
  • Supports applications such as 40G LAN, 100G LAN or OTU4 100Gbps

 

Specifications

  • Cable type: 3.2 mm round LSZH jacketed cable
  • Bandwidth fiber: Multimode OM3 XG lazer optimized ≥2000MHzxKm @850nm
  • Single Mode OS2 ITU-T G.652d 9micron
  • Connector-Type: High connectivity MPO
  • Connector Interface: MPO interface requirements: IEC61754-4.20 and IEC61754-7
  • Connector End face: MPO end face geometry requirements: EN50377-15-1
  • Polishing Quality: Polished end-face quality: IEC61300-3-35
  • Insertion Loss: ≤ 0.5dB OM3 / ≤ 0.6dB SM OS2
  • Return Loss: ≥ 25dB OM3; ≥ 35dB

Ordering Information

o mp

 

Support

Starview Tech Support & Customer Service access you to open troubleshooting tickets

Features

• 0.35dB for all MM, SM Low Loss 0.35dB & Standard Loss 0.60dB
• 100% Interferometer Test
• IEC 61754-7 and TIA/EIA 604-5 Compliant for MPO interfaces

 

Standard Compliance

• EIA/TIA-455-21A
• TIA 604-5 (FOCIS 5)
• Telcordia GR-326-CORE
• IEC61754-7

 

Applications

• Data Centre Infrastructure
• Storage Area Network – Fiber Channel
• Parallel Optics
• 10Gbps, 25Gbps and emerging 40Gbps, 100Gbps Protocol

 

MPO to 4 duplex LC breakout cable fan out a single 40Gbps connection from a 40GBase-SR4 QSFP+ optical transceiver module to four 10Gbps LC SFP+ optical transceiver modules, while 12 fiber type is used in 10G networks. The MPO to LC breakout cable is also an economical solution for a smaller network environment in which you don’t need complicated equipment, because the MPO cable allows redistribution of various fibers into one round cable for short distance transmission, it offers 12, 24 and up to 144 fibers for these applications. To protect the cable in the harsh environment, armored cable is available. OM3 & OM4 types MPO-LC breakout cable are very popular in markets. You might see both aqua and magenta colors are used for OM4 cable, it’s just choice by different markets. MPO breakout cable offers up to 144 fibers, but most common versions are 12 and 24.

 

Specifications

  • Optical Properties
    • Attenuation (dB/km)
    Single Mode:≤ 0.32 at 1310nm, ≤ 0.18 at 1550nm
    Multi Mode:≤ 2.3 at 850nm, ≤ 0.6 at 1300nm
    • Insertion Loss (dB)
    Single Mode: Elite: ≤ 0.35, Standard: ≤ 0.75
    Multi Mode:Elite: ≤ 0.35, Standard: ≤ 0.6
    • Return Loss (dB)
    Single Mode:UPC: ≥ 50
    Multi Mode:UPC: ≥ 20
    • Connector Type
    LC
    • Insertion Loss (dB)
    Single Mode:UPC: ≤ 0.25
    Multi Mode:UPC: ≤ 0.25
    • Return Loss (dB)
    Single Mode:UPC: ≥ 50
    Multi Mode:UPC: ≥ 30


    Specifications
    • Fiber Mode
    Single Mode: OS2 9/125μm
    Multimode: OM4, OM3, OM2 50/125μm, OM1 62.5/125μm
    • Connector A:MPO Female, Male
    • Connector B:LC
    • Polish Type
    Single Mode: UPC Muliti Mode: UPC
    • Cable Jacket:LSZH, PVC
    • Cable Type:Round, Ribbon
    • Cable Diameter:3.0mm
    • Breakout:0.9/2.0mm
    • Breakout Length:0.5M
    • Transmission Distance
    OM4: 150m @40/100G, 400m @10G
    OM3: 100m @40/100G, 300m @10G

Ordering Information

o_mpb

 

Support

Starview Tech Support & Customer Service access you to open troubleshooting tickets

Duplex Multimode Patch Cord

Features

  • Different type of terminations SC to ST, LC to FC, etc.
  • ANSI/TIA/EIA-568.B.3 compliant
  • 50/125µm, 62.5/125µm Multimode Riser
  • 1.6mm, 2mm, and 3mm Simplex / Duplex
  • IEEE 802.3u, IEC 60794, TIA/EIA-568.B.3 compliant
  • Electric interference immune
  • Fibers offers low insertion loss once joined to connector
  • Telcordia GR-326 tested
  • Lab connectorized, each jumpers includes a quality certificate to state measuring standards
 

Specifications

  • SC Connector Dimensions: 10.6mm Height x 26mm Width x 58mm Depth (with installed duplex clip)
  • Maximum Connector Loss: 0.50 dB
  • Typical Connector Loss: 0.30 dB
  • Typical Return Loss: -25 dB
  • Buffer Material: PVC
  • Buffer OD: 900 µm
  • Jacket Material: PVC (OFNR riser-rated)
  • Jacket OD: 2.8 mm
  • Installation Tensile Load: 100 N (445 lbs)
  • Long-Term Tensile Load: 50 N (222 lbs)
  • Maximum Tensile Load: 100 N/cm
  • Installation (Loaded) Minimum Bend Radius: 5.0cm (1.97in)
  • Long-Term (Unloaded) Minimum Bend Radius: 3.0cm (1.2in)
  • Crush Resistance: 750 N/cm
  • Impact Resistance: 1,000 cycles
  • Flex Resistance: 5,000 cycles
  • Attenuation at 1300 nm: 1.0 dB/km
  • Attenuation at 850 nm: 3.5 dB/km
  • Operating Temperature: -20°C to +70°C

Ordering Information

o i dm

Support

Starview Tech Support & Customer Service access you to open troubleshooting tickets

Armour Fiber Patch Cord

Starview armour fiber patch cord retains all the features of standard jumpers, but it is much stronger. With stainless steel tube inside the outer jacket to protect the central unit of the cable, the starview armour fiber patch cord is ideal to use in harsh environment. It is flexible but extreme resistant, anti-rodent and able to bend without being broken.

Features

  • Resist damage by improper twist
  • Resistance of pressure and rodent bite
  • Fibers offers low insertion loss once joined to connector
  • 1.6mm and 2mm Simplex / Duplex
  • Fibers offers low insertion loss once joined to connector
  • IEEE 802.3u, IEC 60794, TIA/EIA-568.B.3 compliant
  • 50/125µm Multi Mode, 62.5/125µm Single Mode, 3mm Simplex
  • Stainless steel tube inside the outer jacket
  • Additional durability and protection as well as light weight.
  • Different type of terminations SC to ST, LC to FC, etc.
 

Specifications

  • Standards:Telcordia GR-326, IEEE 802.3u/802.3x/802.3z/802.3j, IEC 60794, TIA/EIA-568.B.3
  • Fiber Jacket
  • Color: Multimode: gray/orange Single mode: blue
  • Diameter:3mm ± 0.05mm
  • Thickness:0.80mm ± 0.80mm
  • Temperature:-20°C up to 85°C
  • Fiber optic
  • Core diameter
  • Fiber:9/125µm, 50/125µm, 62.5/125µm
  • Value: ± 0.70mm
  • Cladding diameter:125.0 ± 2.0µm
  • Core concentricity : <=1.5µm
  • Cladding concentricity :<=1.0%
  • Wavelength
    Multimode: 850 nm / 1300 nm
  • Single mode: 1310 nm / 1150 nm
  • Maximum value:<=0.03 / <=0.02
  • Recommended Light source
  • Multimode:LED o VCSEL
  • Single mode:Laser

Ordering Information

o i Asm

Support

Starview Tech Support & Customer Service access you to open troubleshooting tickets

Duplex Single Mode Patch Cord

Features

  • Different type of terminations SC to ST, LC to FC, etc.
  • ANSI/TIA/EIA-568.B.3 compliant
  • 50/125µm, 62.5/125µm Multimode Riser
  • 1.6mm, 2mm, and 3mm Simplex / Duplex
  • IEEE 802.3u, IEC 60794, TIA/EIA-568.B.3 compliant
  • Electric interference immune
  • Fibers offers low insertion loss once joined to connector
  • Telcordia GR-326 tested
  • Lab connectorized, each jumpers includes a quality certificate to state measuring standards
 

Specifications

  • Maximum Connector Loss: 0.50 dB
  • Typical Connector Loss: 0.30 dB
  • Typical Return Loss: -55 dB
  • Buffer Material: PVC
  • Buffer OD: 900 µm
  • Jacket Material: PVC (OFNR riser-rated)
  • Jacket OD: 1.8 mm
  • Installation Tensile Load: 100 N (445 lbs)
  • Long-Term Tensile Load: 50 N (222 lbs)
  • Maximum Tensile Load: 100 N/cm
  • Installation (Loaded) Minimum Bend Radius: 5.0cm (1.97in)
  • Long-Term (Unloaded) Minimum Bend Radius: 3.0cm (1.2in)
  • Crush Resistance: 750 N/cm
  • Impact Resistance: 1,000 cycles
  • Flex Resistance: 5,000 cycles
  • Attenuation at 1550 nm: 0.25 dB/km
  • Attenuation at 1310 nm: 0.35 dB/km
  • Operating Temperature: -20°C to +70°C

Ordering Information

o i ds

Support

Starview Tech Support & Customer Service access you to open troubleshooting tickets

How to choose optical fiber patch cord?

The Optial Fiber Patch Cord is available for any kind of configurations you need.

ordering

Take me to choose a connector!

Transceiver-Overview!

Technical Support


+65 6100 DESK (+65 6100 3375)
Customer Portal
Facebook
LinkedIn

Location


Singapore Headquarters
60 Kaki Bukit Place #05-19 Eunos Techpark
Singapore 415979

Tel: +65 3157 5338
Fax: +65 3112 8181

© 2018 Starview International. All Rights Reserved.